Field Engineering Support
Our veteran fluid technicians provide on-site support with technical services, inventory management, and our exclusive QA/QC program which includes pre-job, real-time, and post job testing and data tracking.
The Industry Leader
Frac Job Planning and Execution
Job Set-Up Through Completion Process
Job Information Received
- Location
- Design
- Rate of consumption
Pre-Job Set-Up Plan
- Tanks, pumps, lab trailer
- Containment
- Rig up procedure
Job Execution
- Safety Meetings
- QA/QC
- Receive Deliveries
- Usage report signed by frac/customer
- Tank Level/Inventory Mgmt
- Collect next pad H2O for analysis
- Daily ticket logs
Rig Down Process
- Final ticket report
- Rig down procedure
- Journey to next location
What We Do
Have Questions?
Call Us Today!
866-452-5276
or832-206-0790
Job Execution
QA/QC Lab Trailer
- Thermometer
- pH Probe/strips
- Fann 35 Viscometer
- Blender
- Hydrometer
- Incubator
- Water Analysis Kit
CrudeChem QA/QC Program
- Pre-job compatibility testing with source waters
- Real-time job monitoring of chlorides, specific gravity, pH, ORP, and viscosity for basic designs along with bug bottles every 10 stages to verify the efficacy of the biocide program.
- We expand as needed for more technical designs to include break profiles and crosslink time/quality
- Post Frac Monitoring - 30 Days into Production
- Complete water analysis, including acid gases
- Water sample visually checked for signs of polymer or emulsification
- Oil sample analyzed for signs of polymer or emulsions emulsification
- Test water for biocide efficacy; APB/SRB serial dilution bottles
- If solids/goo samples are available, test solids for solids; scale/iron sulfide/ FR. FR can be detected by running sample through FTIR
Inventory Management (On-Site)
- On-Site delivery and consumption tracking
- Remote tank level monitoring
- Mobile App Chemical metrics
- Re-stock notifications
Stage Report Example
Well # | Stage # | DATE | Start Time | End Time | SPEC GRA | CHLORIDE | PH | ORP | FR USAGE | FR FRAC | BOI USAGE | BIO FRAC | POP | CLEAN BARRELS | FR AVERAGE GPT | BIO AVERAGE GPT |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
6H | 44 | 3/27/2021 | 6:45:00 PM | 8:39:00 PM | 1.04 | 32,000 | 6.24 | 450.0 mV | 233.0 gal | 228.0 gal | 101.0 gal | 97.0 gal | 0.0 gal | 9,126 bbl | 0.61 | 0.26 |
6H | 45 | 3/28/2021 | 2:29:00 AM | 4:15:00 AM | 1.05 | 23,704 | 6.73 | 490.0 mV | 236.0 gal | 229.0 gal | 103.0 gal | 95.0 gal | 0.0 gal | 9,120 bbl | 0.62 | 0.27 |
6H | 46 | 3/28/2021 | 12:56:00 PM | 2:41:00 PM | 1.03 | 16,592 | 6.95 | 350.0 mV | 195.0 gal | 193.0 gal | 101.0 gal | 95.0 gal | 0.0 gal | 8,883 bbl | 0.52 | 0.27 |
6H | 47 | 3/28/2021 | 9:41:00 PM | 11:27:00 PM | 1.03 | 17,778 | 6.97 | 285.0 mV | 240.0 gal | 232.0 gal | 103.0 gal | 97.0 gal | 0.0 gal | 9,024 bbl | 0.63 | 0.27 |
6H | 48 | 3/29/2021 | 4:47:00 AM | 6:31:00 AM | 1.04 | 17,778 | 7.00 | 350.0 mV | 204.0 gal | 194.0 gal | 103.0 gal | 96.0 gal | 0.0 gal | 8,906 bbl | 0.55 | 0.28 |
6H | 49 | 3/29/2021 | 11:32:00 AM | 1:15:00 PM | 1.02 | 16,592 | 6.99 | 362.0 mV | 169.0 gal | 154.0 gal | 94.0 gal | 95.0 gal | 0.0 gal | 8,839 bbl | 0.46 | 0.25 |
6H | 50 | 3/29/2021 | 7:58:00 PM | 10:14:00 PM | 1.04 | 17,778 | 6.94 | 366.0 mV | 214.0 gal | 206.0 gal | 86.0 gal | 87.0 gal | 0.0 gal | 8,657 bbl | 0.59 | 0.24 |
6H | 51 | 3/30/2021 | 3:11:00 AM | 7:51:00 AM | 1.06 | 21,333 | 6.79 | 448.0 mV | 255.0 gal | 245.0 gal | 105.0 gal | 99.0 gal | 0.0 gal | 9,873 bbl | 0.61 | 0.25 |